Description
VISCOMETER PACKAGES
Designation | Viscosity range (mPa.s) |
---|---|
FIRST PLUS VISCOMETER WITH SPINDLE RV-2 TO RV-7 (with standard stand) | 200 to 240M |
FIRST PLUS VISCOMETER WITH SPINDLE RV-2 TO RV-7 (with rack stand) | 200 to 240M |
FIRST PLUS LR VISCOMETER WITH SPINDLE LV-1 TO LV-4 (with standard stand) | 15(1*) to 22M |
FIRST PLUS LR VISCOMETER WITH SPINDLE LV-1 TO LV-4 (with rack stand) | 15(1*) to 22M |
NEED HELP FINDING THE BEST SETUP FOR YOUR VISCOMETER?
Our Team will go through your specific requiments and offer the best solution possible.
VISCOMETER STAND OPTIONS
STANDARD STAND
The standard stand allows you to install your viscometer or rheometer on table.
Thanks to its stop ring, it is recommended when the height of the measurement position is constant. Included according to instrument model, it includes a rod, a stop ring, a safety sleeve, a arm and a base
RACK STAND
The rack stand allows you to install your viscometer or rheometer on table.
Thanks to its notched rod system, it allows easy vertical movement of measuring head and is recommended when height of measuring position varies according to container or measuring spindle used. Included according to
instrument models, it includes a notched shank, arm and base.
VISCOMETER SPECIFICATION
Type of instrument
Rotating springless viscometer with 7’’ Touch
screen
Rotation speeds
Unlimited number of speeds between 0.3 and
250 rpm
Torque range
Standard Version: 0.05 to 13 mNm
LR version: 0.005 to 0.8 mNm
Temperature :
The FIRST PLUS has a PT100 sensor which indicates temperatures between -50 °C to + 300 °C.
Accuracy
+/- 1 % of the full scale
Repeatability
+/- 0,2 %
Norms
ASTM : D115 ; D789 ; D1076 ; D1084 ;
D1337 ; D1338 ; D1417; D1439 ; D1824 ;
D2196 ; D2243 ; D2364 ; D2556 ; D3288 ;
D3468 ; D3716 ; D3730 ; D3794 ; D4016 ;
D4143 ; D4878 ; D4889 ; D5324 ; D5400 ;
D6279 ; D6577 ; D7394 ; D8020 ; E2975 ;
F1607 ; BS 5350 ; DIN 2555 ; 3219 ; 52007-
1 ; 53019-1; 54453 ; EN 302-7 ; 2555 ; 3219
; 10301 ; 12092 ; 12802 ; 15425 ; 15564 ;
ISO 1652 ; 2555 ; 2884-2 ; 3219 ; 10364-12
Display
Viscosity (cP/Poises or mPa.s / Pa.s)-Speed – Shear rate – Torque (%-mNm) – Shear stress – Time – Temperature
Languages
French/English/Russian/Spanish/Turkish/German/Italian/Korean/Portuguese
Supply voltage
90-240 VAC 50/60 Hz
Connection
USB port
Printer connection :
USB Host Port – Compatible PCL/5
Dimensions and weight
Head: D180 x H230 x W130 mm
Alluminium stand: L280 x W200 x H30 mm
Stainless steel rod: Length 500 mm
Weight: 6.7 kg
Compatible measuring systems :
MS DIN, MS RV/LV, MS BV, MS VANE, MS ULV, MS KREBS, MS SV.
Compatible temperature control :
EVA MS-DIN PLUS, EVA LR-BV PLUS, RT-1 PLUS.
NEED HELP ?
Fill in the form and our team of experts will recommend the best viscometer and setup based on your requirements.